The latest information │Energystar version 3 (final draft) of Computer Servers has been published
Publisher:Admin  Source:  Date:2018/7/25

主机2.jpg


Following the release of the Computer Servers version 3 draft (2) on July 31, 2017, EPA again hosted a webinar on May 17, 2018. Taking the feedbacks and the opinions from all parties into consideration, the Computer Servers version 3 (final draft) was finally released in July 11, 2018. The deadline for feedback of the final draft is July 25, 2018, and the effective date is May 10, 2019. Compared with draft 2, the final draft mainly contains the following key changes:


1. EPA updated the previous definition of "Network Equipment" to "Large Network Equipment". The definition is as follows:

                    变化1.PNG

2. EPA updated the definition of "APAs" , which is shown below:

变化2.PNG

3. Except for item A, B and D, the item C and item E in common attribute of series models are updated, they are shown below:

变化3.PNG

 4. The requirements of test configuration for series models are updated. The new requirements are as follows:

For lower-end performance configurations, the additional requirements are: the test configuration shall include storage capacity, of which the figure shall be no less than the product of the DIMM slots number and the minimum DIMM size

For high-end performance configuration, the additional requirements are: the test configuration shall include storage capacity, of which the figure shall be no less than the result of the following formula

变化4-1.PNG

For a typical configuration, the additional requirement is: the test configuration shall include the storage capacity, of which the figure shall be no less than the result of the following formula

变化4-2.PNG

5. The "Network Equipment" in the excluded product range is updated to "Large Network Equipment"


6. Formula 7 is added to calculate Effi. The formula is as follows:

变化6.PNG

7. The energy efficiency limits in the Active state mode is updated as follows:

表1.jpg

8. The energy efficiency requirements of Idle state mode are deleted, but it still needs to be tested and reported


9. About the requirements of APAs(Auxiliary Processing Accelerators), for all computer servers sold with expansion APAs, Active State and Idle State testing shall be only conducted without any APAs installed which may be offered with the product. The testing with APA installed is not required any more; the related requirements are also removed.


10. The testing method of Energystar is updated to Version 2018

表2.jpg

Official link:

https://www.energystar.gov/products/spec/enterprise_servers_specification_version_3_0_pd

 

Service Advantages of BACL:

BACL, as a famous lighting detection expert in North America, FCC, TCB and Energystar certification body and the 16th NRTL safety certification body recognized by the U.S. OSHA, can provide our customers with one-stop testing and certification service on FCC, NRTL, FDA, Energystar, DLC, Lighting Facts Label, DOE, CE, CB, PSE, SAA, CEC, CEC Title 20, CEC Title 24, FTC, and so force, with over twenty years’ experience in test and comprehensive authorizations.